Okebiz Video Search



Title:Why Do We BOND Neutral & Ground in ELECTRICAL SERVICE PANELS?
Duration:17:05
Viewed:717,006
Published:05-04-2021
Source:Youtube

This question has been asked by so many people over such a long time. Why on earth do we have to bond the system neutral and the equipment grounding conductors, and grounding electrode conductors in an electrical system? Join this channel to get access to perks: https://www.youtube.com/channel/UCB3j... 👾🤖PRACTICE EXAMS🤖👾 https://www.electricianu.com/practice... 😎👕MERCH👕😎 https://www.electricianu.com/merchandise 📲👥SOCIALS👥📲 Instagram - https://www.instagram.com/electrician_u Discord - https://discord.gg/7ykYfbh Facebook Page - https://www.facebook.com/theelectricianu Facebook Group - https://bit.ly/2tz7eQh TikTok - https://www.tiktok.com/@electricianu Reddit- https://www.reddit.com/r/ElectricianU/ Twitter - https://www.twitter.com/electrician_u LinkedIn - www.linkedin.com/in/dustinstelzer 🎧🎹MUSIC AND VIDEO:🎹🎧 https://www.facebook.com/descantmv 🎬✍️ART AND ILLUSTRATION:✍️🎬 https://www.daverussoart.com Well, it really comes down to "Because the National Electrical Code Says So" but there is a reason behind all of it. We didn't have equipment grounding conductors back in the day, it was simply neutral and hot. As people began getting shocked when touching pieces of metal we devised a way to link all metal things around electrical equipment, together, and make them one continuous piece of metal. Circuit breakers are designed to shut off power when electrical current goes through it at a high enough level. Allowing current to flow on these metal parts is extremely dangerous, so we need a way to make the current shut off when this happens. By bonding the equipment grounding conductors to the system neutral, there is now a path back to the transformer from where the power came. This allows for a full circuit to be formed, which will allow current to flow through the breaker in a complete circle from source, back to source, rather than just from source, to earth (where the breaker will not trip). Bonding and Grounding are very complex subjects, which is why Article 250 of the National Electrical Code is one of the biggest sections of the codebook. There's so much to know, and it all deals with saving lives, preventing injuries, and protecting equipment from damage. #grounding #bonding #groundingvsbonding

SHARE TO YOUR FRIENDS


Download Server 1


DOWNLOAD MP4

Download Server 2


DOWNLOAD MP4

Alternative Download :



SPONSORED
Loading...
RELATED VIDEOS
Why Neutrals & Grounds are Connected in a Main Panel Why Neutrals & Grounds are Connected in a Main ...
20:13 | 602,609
What is a Floating Neutral Generator? What is a Floating Neutral Generator?
27:56 | 212,086
Difference Between VOLTAGES - Why We Need Them All Difference Between VOLTAGES - Why We Need Them All
13:43 | 324,877
Why 3 Phase AC instead of Single Phase??? Why 3 Phase AC instead of Single Phase???
10:57 | 837,125
Holey Plugs, Batman! But... what are they for? Holey Plugs, Batman! But... what are they for?
20:32 | 406,322
Why Neutrals and Grounds are Separated in a Sub Panel Why Neutrals and Grounds are Separated in a Sub...
17:46 | 456,567
Arc-Fault, Ground-Fault, and Dual-Function Circuit Breakers Explained Arc-Fault, Ground-Fault, and Dual-Function Circ...
19:51 | 84,754
THIS IS WHY ELECTRICIANS DON'T HIDE J-BOXES IN WALLS - Finding Hackwork!! THIS IS WHY ELECTRICIANS DON'T HIDE J-BOXES IN ...
30:07 | 188,888

shopee ads

coinpayu